Division 7 Putting into use
United Kingdom
Table 5
| However, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers. | |
| Note: However, the manufacturer may specify a better accuracy for a certain type of measuring system. | |
| Accuracy Class | Types of Measuring system |
|---|---|
| 0,3 | Measuring systems on pipeline |
| 0,5 | All measuring systems if not differently stated elsewhere in this Table, in particular:
|
| 1,0 | Measuring systems for liquefied gases under pressure measured at a temperature equal to or above – 10 °C |
| Measuring systems normally in class 0,3 or 0,5 but used for liquids
| |
| 1,5 | Measuring systems for liquefied carbon dioxide |
| Measuring systems for liquefied gases under pressure measured at a temperature below – 10 °C (other than cryogenic liquids) | |
| 2,5 | measuring systems for cryogenic liquids (temperature below – 153 °C) |
Annotations
Footnotes
- f1
-
However, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers.