OpenLegislation

Division 7 Putting into use

United Kingdom

Original text. Later amendments are not shown.

Table 5

However, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers.

Note: However, the manufacturer may specify a better accuracy for a certain type of measuring system.

Accuracy ClassTypes of Measuring system
0,3Measuring systems on pipeline
0,5

All measuring systems if not differently stated elsewhere in this Table, in particular:

  • fuel dispensers (not for liquefied gases),

  • measuring systems on road tankers for liquids of low viscosity (< 20 mPa.s)

  • measuring systems for (un)loading ships and rail and road tankersf1

  • measuring systems for milk

  • measuring systems for refuelling aircraft

1,0Measuring systems for liquefied gases under pressure measured at a temperature equal to or above – 10 °C

Measuring systems normally in class 0,3 or 0,5 but used for liquids

  • whose temperature is less than – 10 °C or greater than 50 °C

  • whose dynamic viscosity is higher than 1 000 mPa.s

  • whose maximum volumetric flowrate is not higher than 20 L/h

1,5Measuring systems for liquefied carbon dioxide
Measuring systems for liquefied gases under pressure measured at a temperature below – 10 °C (other than cryogenic liquids)
2,5measuring systems for cryogenic liquids (temperature below – 153 °C)

Annotations

Footnotes

f1

However, Member States may require measuring systems of accuracy class 0,3 or 0,5 when used for the levying of duties on mineral oils when (un)loading ships and rail and road tankers.