OpenLegislation

Division 3 APPARATUSF1

United Kingdom

Original text. Later amendments are not shown.

The usual laboratory equipment and in particular the following:

  1. 3.1.

    Round bottomed flask fitted with a reflux condenser with ground-glass joints, 250 mL.

  2. 3.2.

    Separating funnel, 500 mL.

  3. 3.3.

    Flasks, 250 mL.

  4. 3.4.

    Microsyringes, 100 μL and 500 μL.

  5. 3.5.

    Cylindrical filter funnel with a G3 porous septum (porosity 15-40 μm) of diameter approximately 2 cm and a depth of 5 cm, suitable for filtration under vacuum with male ground-glass joint.

  6. 3.6.

    Conical flask with ground-glass female joint, 50 mL, which can be fitted to the filter funnel (3.5).

  7. 3.7.

    Test tube with a tapering bottom and a sealing glass stopper, 10 mL.

  8. 3.8.

    Calcium dichloride desiccator.

Annotations

Textual amendments

F1

Substituted by Commission Implementing Regulation (EU) 2019/1604 of 27 September 2019 amending Regulation (EEC) No 2568/91 on the characteristics of olive oil and olive-residue oil and on the relevant methods of analysis.