Division 5.1.1 Temperature conditioning testF1

United Kingdom

Original text. Later amendments are not shown.

In a dedicated temperature chamber, the canister(s) is (are) cycled between temperatures from – 15 °C to 60 °C, with 30 min of stabilisation at – 15 °C and 60 °C. Each cycle shall last 210 min as in Figure 3. The temperature gradient shall be as close as possible to 1 °C/min. No forced air flow should pass through the canister(s).

The cycle is repeated 50 times consecutively. In total, this operation will last 175 hours.