OpenLegislation

Division Results of an interlaboratory test (Informative)F1

United Kingdom

Original text. Later amendments are not shown.

An inter laboratory test was carried out in 2008 with the participation of the European Customs laboratories.

The evaluation of precision data was performed according to the ‘Protocol for the design, conduct and interpretation of method-performance studies’, W. Horwitz, (IUPAC technical report), Pure & Appl. Chem., Vol. 67, N o 2, PP.331-343, 1995.

The precision data are given in the table below.

Samples 1 chocolate and biscuit bar 2 biscuit Z sample 1 Z sample 2
Number of laboratories 41 42
Number of laboratories after eliminating outliers 38 39
Mean (%, m/m) 29,8 55,0
Repeatability standard deviation sr (%, m/m) 0,5 0,5
Reproducibility standard deviation sR (%, m/m) 1,5 2,3
Repeatability limit r (%, m/m) 1,4 1,4
Reproducibility limit R (%, m/m) 4,2 6,6

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) No 118/2010 of 9 February 2010 amending Regulation (EC) No 900/2008 laying down the methods of analysis and other technical provisions necessary for the application of the arrangements for imports of certain goods resulting from the processing of agricultural products.