Division 4.2.10.2.1
The drop tests shall be performed at ambient temperature without internal pressurisation or attached valves. A plug may be inserted in the threaded ports to prevent damage to the threads and seal surfaces.
The surface onto which the container is dropped shall be a smooth, horizontal concrete pad or similar rigid floor.
The container shall be tested in the following sequence:
- (a)
Drop once from a horizontal position with the bottom 1,8 m above the ground;
- (b)
Drop once onto each end of the container from a vertical position with a potential energy ≥ 488 J, but in no case shall the bottom end be more than 1,8 m above the ground;
- (c)
Drop once at a 45° angle, and then for non-symmetrical or non-cylindrical containers rotate the container through 90° along its longitudinal axis and drop again at a 45° angle, with its centre of gravity 1,8 m above the ground. However, if the bottom is closer to the ground than 0,6 m, the drop angle shall be changed to maintain a minimum height of 0,6 m and the centre of gravity 1,8 m above the ground;
- (d)
No attempt shall be made to prevent bouncing of the container, but it may be prevented from falling over during the vertical drop test;
- (e)
Pressure cycle the container between ≤ 2,0 MPa and ≥ 1,25 times nominal working pressure for three times the number of filling cycles calculated in accordance with section 2.7.6.