The acute inhalation toxicity of the active substance shall be reported where any of the following apply:

  • the active substance has a vapour pressure > 1 × 10–2 Pa at 20 °C;

  • the active substance is a powder containing a significant proportion of particles of a diameter < 50 μm ( > 1 % on weight basis);

  • the active substance is included in products that are powders or are applied by spraying.

The head/nose only exposure shall be used, unless whole body exposure can be justified.

Notes on Division 5.2

Footnotes

f1

aAOEL, abbreviation for ‘Acute AOEL’.