Division 3 E TEC , SLEEP MODE, OFF MODE AND LOWEST POWER STATE:F1
United Kingdom
- (1)
For power demand requirements larger than 1,00 W, or where energy consumption requirements formulated in TEC result in a power demand requirement larger than 1,00 W in at least one power mode, the model configuration shall be considered to comply with the applicable requirements set out in points 1.1, 1.2, 1.3, 1.4, 2.2 and 2.3 of Annex II if the test results do not exceed the respective verification tolerances given in the table below.
Verification tolerances for power demand requirements larger than 1,00 W
Requirements set out Verification tolerances Points 1.1, 1.2, 1.3, 1.4 and 2.3 of Annex II The determined value shall not exceed the declared value by more than 7 %. Point 2.2 of Annex II (with and without the additional allowance listed in point 2.4) The determined value shall not exceed the declared value by more than 7 %. The additional allowances provided for in point 2.4 of Annex II can be added to the requirement specified in point 2.2 if the model configuration is placed on the market with a WOL functionality enabled in sleep mode. The model configuration should be tested with WOL functionality both enabled and disabled and should comply with both requirements. The model configuration placed on the market without ethernet capability shall be tested without WOL enabled.
- (2)
For power demand requirements less than or equal to 1,00 W, the model configuration shall be considered to comply with the applicable requirements set out in point 3.1 and 4.1 of Annex II if the test results do not exceed the respective verification tolerances given in the table below.
Verification tolerances for power demand requirements of 1,00 W and smaller
Requirements set out Verification tolerances Point 3.1 of Annex II (with and without the additional allowance specified in point 3.3) The determined value shall not exceed the declared value by more than 0,10 W. Point 4.1 of Annex II (with and without the additional allowances listed in point 4.3) The determined value shall not exceed the declared value by more than 0,10 W. The additional allowance provided for in point 3.3 of Annex II can be added to the requirement specified in point 3.1 if the model configuration is placed on the market with an ‘information or status display’.
The additional allowance provided for in point 4.3 of Annex II can be added to the requirement set out in point 4.1 if the model configuration is placed on the market with a WOL functionality enabled in off mode. The model configuration should be tested with WOL functionality both enabled and disabled and should comply with both requirements. The model configuration placed on the market without ethernet capability shall be tested without WOL enabled.
Annotations
Textual amendments
Notes on Annex III
Textual amendments
- F2
Words in Annex 3 substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 17(7)(a) (as amended by S.I. 2020/1528, regs. 1(2), 6(1)(2)(b)(xvi)); 2020 c. 1, Sch. 5 para. 1(1)