Division 4.2.9.1 Contact wire heightF1
United Kingdom Repealed
- (1)
The permissible data for contact wire height is given in Table 4.2.9.1.
- (2)
For the relation between the contact wire heights and pantograph working heights see EN 50119:2009 figure 1.
- (3)
At level crossings the contact wire height shall be specified by national rules or in the absence of national rules, according to EN 50122-1:2011, clauses 5.2.4 and 5.2.5.
- (4)
For the track gauge system 1 520 and 1 524 mm the values for contact wire height are as follows:
- (a)
Nominal contact wire height: between 6 000 mm and 6 300 mm;
- (b)
Minimum design contact wire height: 5 550 mm;
- (c)
Maximum design contact wire height: 6 800 mm.
- (a)
Annotations
Textual amendments
- F1
Regulation revoked (31.12.2020) by The Railways (Interoperability) (Miscellaneous Amendments and Revocations) (EU Exit) Regulations 2020 (S.I. 2020/318), reg. 1(2)(c), Sch. 2