    From 1 January 2018 the following product information on local space heaters shall be provided:

    1. (i)

      the instruction manuals for installers and end-users, and free access websites of manufacturers, their authorised representatives and importers shall contain the following elements:

      1. (1)

        for gaseous or liquid fuel local space heaters, the information set out in Table 1, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;

      2. (2)

        for electric local space heaters, the information set out in Table 2, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;

      3. (3)

        for commercial local space heaters, the information set out in Table 3, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;

      4. (4)

        any specific precautions that must be taken when the local space heater is assembled, installed or maintained;

      5. (5)

        information relevant to disassembly, recycling and/or disposal at end-of-life;

    2. (ii)

      the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:

      1. (1)

        the elements specified in point (a);

      2. (2)

        a list of all equivalent models, if applicable.

  2. (b)

    From 1 January 2018 the following product information on local space heaters shall be provided:

    1. (i)

      for flueless local space heaters and open to chimney local space heaters only: the instruction manual for end-users, free access websites of manufacturers and the product packaging shall incorporate the following sentence in such a way to ensure clear visibility and legibility and in a language easily understood by the end-users of the Member State where the product is marketed: ‘This product is not suitable for primary heating purposes’;

      1. (1)

        for the instruction manual for end-users this sentence shall be on the cover page of the manual;

      2. (2)

        for free-access websites of manufacturers this sentence shall be displayed together with the other characteristics of the product;

      3. (3)

        for the product packaging the sentence shall be placed in a prominent position in the packaging when displayed to the end-user prior to purchase;

    2. (ii)

      for electric portable local space heaters only: the instruction manual for end-users, free access websites of manufacturers and the product packaging shall incorporate the following sentence in such a way to ensure clear visibility and legibility and in a language easily understood by the end-users of the Member State where the product is marketed: ‘This product is only suitable for well insulated spaces or occasional use.’:

      1. (1)

        for the instruction manual for end-users this sentence shall be on the cover page of the manual;

      2. (2)

        for free-access websites of manufacturers this sentence shall be displayed together with the other characteristics of the product;

      3. (3)

        for the product packaging the sentence shall be placed in a prominent position in the packaging when displayed to the end-user prior to purchase.

Table 1

Information requirements for gaseous/liquid fuel local space heaters

NOx
  • nitrogen oxides

  • Model identifier(s):
    Indirect heating functionality: [yes/no]
    Direct heat output: …(kW)
    Indirect heat output: …(kW)
    Fuel Space heating emissionsf1
    NOx
    Select fuel type[gaseous/liquid][specify] [mg/kWhinput] (GCV)
    ItemSymbolValueUnitItemSymbolValueUnit
    Heat output Useful efficiency (NCV)
    Nominal heat output Pnom x,xkWUseful efficiency at nominal heat output ηth,nom x,x%
    Minimum heat output (indicative) Pmin [x,x/N.A.]kWUseful efficiency at minimum heat output (indicative) ηth,min [x,x/N.A.]%
    Auxiliary electricity consumption Type of heat output/room temperature control (select one)
    At nominal heat output elmax x,xxxkWsingle stage heat output, no room temperature control[yes/no]
    At minimum heat output elmin x,xxxkWtwo or more manual stages, no room temperature control[yes/no]
    In standby mode elSB x,xxxkWwith mechanic thermostat room temperature control[yes/no]
    with electronic room temperature control[yes/no]
    with electronic room temperature control plus day timer[yes/no]
    with electronic room temperature control plus week timer[yes/no]
    Other control options (multiple selections possible)
    room temperature control, with presence detection[yes/no]
    room temperature control, with open window detection[yes/no]
    with distance control option[yes/no]
    with adaptive start control[yes/no]
    with working time limitation[yes/no]
    with black bulb sensor[yes/no]
    Permanent pilot flame power requirement
    Pilot flame power requirement (if applicable) Ppilot [x,xxx/N.A.]kW
    Contact detailsName and address of the manufacturer or its authorised representative.

    Table 2

    Information requirements for electric local space heaters

    Model identifier(s):
    ItemSymbolValueUnitItemUnit
    Heat output Type of heat input, for electric storage local space heaters only (select one)
    Nominal heat output Pnom x,xkWmanual heat charge control, with integrated thermostat[yes/no]
    Minimum heat output (indicative) Pmin [x,x/N.A.]kWmanual heat charge control with room and/or outdoor temperature feedback[yes/no]
    Maximum continuous heat output Pmax,c x,xkWelectronic heat charge control with room and/or outdoor temperature feedback[yes/no]
    Auxiliary electricity consumption fan assisted heat output[yes/no]
    At nominal heat output elmax x,xxxkW Type of heat output/room temperature control (select one)
    At minimum heat output elmin x,xxxkWsingle stage heat output and no room temperature control[yes/no]
    In standby mode elSB x,xxxkWTwo or more manual stages, no room temperature control[yes/no]
    with mechanic thermostat room temperature control[yes/no]
    with electronic room temperature control[yes/no]
    electronic room temperature control plus day timer[yes/no]
    electronic room temperature control plus week timer[yes/no]
    Other control options (multiple selections possible)
    room temperature control, with presence detection[yes/no]
    room temperature control, with open window detection[yes/no]
    with distance control option[yes/no]
    with adaptive start control[yes/no]
    with working time limitation[yes/no]
    with black bulb sensor[yes/no]
    Contact detailsName and address of the manufacturer or its authorised representative.

    Table 3

    Information requirements for commercial local space heaters

    NOx
  • nitrogen oxides.

  • For luminous local space heaters the weighted thermal efficiency is by default 85,6 %.

    Model identifier(s):
    Type of heating:[luminous/radiant tube]
    Fuel Fuel Space heating emissionsf2
    NOx
    Select fuel type[gaseous/liquid][specify] mg/kWhinput (GCV)
    Characteristics when operating with the preferred fuel only
    ItemSymbolValueUnitItemSymbolValueUnit
    Heat output Useful efficiency (GCV) — tube local space heaters only f3
    Nominal heat output Pnom x,xkWUseful efficiency at nominal heat output ηth,nom x,x%
    Minimum heat output Pmin [x,x/N.A.]kWUseful efficiency at minimum heat output ηth,min [x,x/N.A.]%
    Minimum heat output (as percentage of nominal heat output)..[x]%
    Nominal tube system heat output (if applicable) Psystem x,xkW
    Nominal tube segment heat output (if applicable) Pheater,i [x,x/N.A.]kWUseful efficiency of tube segment at minimum heat output (if applicable) ηi [x,x/N.A.]%
    (repeat for multiple segments, if applicable)..[x,x/N.A.]kW(repeat for multiple segments, if applicable)..[x,x/N.A.]%
    number of identical tube segments n [x][-]
    Radiant factor Envelope losses
    radiant factor at nominal heat output RFnom [x,x][-]Envelope insulation class U W/(m2K)
    radiant factor at minimum heat output RFmin [x,x][-]Envelope loss factor Fenv [x,x]%
    radiant factor of tube segment at nominal heat output RFi [x,x][-]Heat generator to be installed outside the heated area[yes/no]
    (repeat for multiple segments, if applicable)..
    Auxiliary electricity consumption Heat output control type (select one)
    At nominal heat output elmax x,xxxkW

    —

    single stage

    [yes/no]
    At minimum heat output elmin x,xxxkW

    —

    two stage

    [yes/no]
    In standby mode elSB x,xxxkW

    —

    modulating

    [yes/no]
    Permanent pilot flame power requirement
    Pilot flame power requirement (if applicable) Ppilot [x,xxx/N.A.]kW
    Contact detailsName and address of the manufacturer or its authorised representative.

    Annotations

    Footnotes

    f1
    NOx
  • nitrogen oxides

  • f2
    NOx
  • nitrogen oxides.

  • f3

    For luminous local space heaters the weighted thermal efficiency is by default 85,6 %.