Division 4.3.1.3.3 The sample preconditioning unit shall:

Original text. Later amendments are not shown.

  1. (a)

    Be capable of diluting the sample in one or more stages to achieve a particle number concentration below the upper threshold of the single particle count mode of the PNC and a gas temperature below 35 °C at the inlet to the PNC;

  2. (b)

    Include an initial heated dilution stage that outputs a sample at a temperature of ≥ 150 °C and ≤ 350 °C ± 10 °C, and dilutes by a factor of at least 10;

  3. (c)

    Control heated stages to constant nominal operating temperatures, within the range ≥ 150 °C and ≤ 400 °C ± 10 °C;

  4. (d)

    Provide an indication of whether or not heated stages are at their correct operating temperatures;

  5. (e)

    Be designed to achieve a solid particle penetration efficiency of at least 70 per cent for particles of 100 nm electrical mobility diameter;

  6. (f)

    Achieve a particle concentration reduction factor fr(di) for particles of 30 nm and 50 nm electrical mobility diameters that is no more than 30 per cent and 20 per cent respectively higher, and no more than 5 per cent lower than that for particles of 100 nm electrical mobility diameter for the VPR as a whole;

    The particle concentration reduction factor at each particle size fr(di) shall be calculated using the following equation:

    frdi=NindiNoutdi

    where:

    Nin(di)
  7. is the upstream particle number concentration for particles of diameter di;

  8. Nout(di)
  9. is the downstream particle number concentration for particles of diameter di;

  10. di
  11. is the particle electrical mobility diameter (30, 50 or 100 nm).

  12. Nin(di) and Nout(di) shall be corrected to the same conditions.

    The arithmetic average particle concentration reduction factor at a given dilution setting fr– shall be calculated using the following equation:

    fr–=fr30nm+ fr50nm+ fr100nm3

    It is recommended that the VPR is calibrated and validated as a complete unit;

  • (g)

    Be designed according to good engineering practice to ensure particle concentration reduction factors are stable across a test;

  • (h)

    Also achieve > 99,0 per cent vaporization of 30 nm tetracontane (CH3(CH2)38CH3) particles, with an inlet concentration of ≥ 10 000 per cm3, by means of heating and reduction of partial pressures of the tetracontane.