Division 4.3.1.3.4 The PNC shall:
- (a)
Operate under full flow operating conditions;
- (b)
Have a counting accuracy of ± 10 per cent across the range 1 per cm3 to the upper threshold of the single particle count mode of the PNC against a suitable traceable standard. At concentrations below 100 per cm3, measurements averaged over extended sampling periods may be required to demonstrate the accuracy of the PNC with a high degree of statistical confidence;
- (c)
Have a resolution of at least 0.1 particles per cm3 at concentrations below 100 per cm3;
- (d)
Have a linear response to particle number concentrations over the full measurement range in single particle count mode;
- (e)
Have a data reporting frequency equal to or greater than a frequency of 0,5 Hz;
- (f)
Have a t90 response time over the measured concentration range of less than 5 seconds;
- (g)
Incorporate a coincidence correction function up to a maximum 10 per cent correction, and may make use of an internal calibration factor as determined in paragraph 5.7.1.3.of this Sub-Annex but shall not make use of any other algorithm to correct for or define the counting efficiency;
- (h)
Have counting efficiencies at the different particle sizes as specified in Table A5/2.
| Table A5/2 | |
| PNC counting efficiency | |
| Particle size electrical mobility diameter (nm) | PNC counting efficiency (per cent) |
|---|---|
| 23 ± 1 | 50 ± 12 |
| 41 ± 1 | > 90 |