For methane measurement using an NMC-FID, the calculation of NMHC depends on the calibration gas/method used for the zero/calibration adjustment.

The FID used for the THC measurement (without NMC) shall be calibrated with propane/air in the normal manner.

For the calibration of the FID in series with an NMC, the following methods are permitted:

  1. (a)

    The calibration gas consisting of propane/air bypasses the NMC;

  2. (b)

    The calibration gas consisting of methane/air passes through the NMC.

It is highly recommended to calibrate the methane FID with methane/air through the NMC.

In case (a), the concentration of CH4 and NMHC shall be calculated using the following equations:

CCH4=CHCw∕NMC−CHCw∕oNMC×1−EERfCH4×EE−EM

CNMHC=CHCw∕oNMC×1−EM−CHCw∕NMCEE−EM

If RfCH4 < 1,05, it may be omitted from the equation above for CCH4.

In case (b), the concentration of CH4 and NMHC shall be calculated using the following equations:

CCH4=CHCw∕NMC×RfCH4×1−EM−CHCw∕oNMC×1−EERfCH4×EE−EM

CNMHC=CHCw∕oNMC×1−EM−CHCw∕NMC×RfCH4×1−EMEE−EM

where:

CHC(w/NMC)
  • is the HC concentration with sample gas flowing through the NMC, ppm C;

  • CHC(w/oNMC)
  • is the HC concentration with sample gas bypassing the NMC, ppm C;

  • RfCH4
  • is the methane response factor as determined per paragraph 5.4.3.2. of Sub-Annex 5;

  • EM
  • is the methane efficiency as determined per paragraph 3.2.1.1.3.3.1. of this Sub-Annex;

  • EE
  • is the ethane efficiency as determined per paragraph 3.2.1.1.3.3.2. of this Sub-Annex.

  • If RfCH4 < 1,05, it may be omitted in the equations for case (b) above for CCH4 and CNMHC.

    Annotations

    Textual amendments

    F1

    Substituted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).