Division 3.3.1 Calculation
PM shall be calculated using the following two equations:
where exhaust gases are vented outside tunnel;
and:
where exhaust gases are returned to the tunnel;
where:
Vmix Vep Pe d
is the volume of diluted exhaust gases (see paragraph 2. of this Sub-Annex), under standard conditions;
is the volume of diluted exhaust gas flowing through the particulate sampling filter under standard conditions;
is the mass of particulate matter collected by one or more sample filters, mg;