OpenLegislation

Division 3.3.1.1 Where correction for the background particulate mass from the dilution system has been used, this shall be determined in accordance with paragraph 2.1.3.1. of Sub-Annex 6. In this case, particulate mass (mg/km) shall be calculated using the following equations:F1

Original text. Later amendments are not shown.

PM=PeVep−PaVap×1−1DF×Vmix+ Vepd

in the case that the exhaust gases are vented outside the tunnel;

and:

PM=PeVep−PaVap×1−1DF×Vmixd

in the case that the exhaust gases are returned to the tunnel;

where:

Vap
  • is the volume of tunnel air flowing through the background particulate filter under standard conditions;

  • Pa
  • is the particulate mass from the dilution air, or the dilution tunnel background air, as determined by the one of the methods described in paragraph 2.1.3.1. of Sub-Annex 6;

  • DF
  • is the dilution factor determined in paragraph 3.2.1.1.1. of this Sub-Annex.

  • Where application of a background correction results in a negative result, it shall be considered to be zero mg/km.

    Annotations

    Textual amendments

    F1

    Substituted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).