Division 3.3.1.1 Where correction for the background particulate mass from the dilution system has been used, this shall be determined in accordance with paragraph 2.1.3.1. of Sub-Annex 6. In this case, particulate mass (mg/km) shall be calculated using the following equations:F1
in the case that the exhaust gases are vented outside the tunnel;
and:
in the case that the exhaust gases are returned to the tunnel;
where:
Vap Pa DF
is the volume of tunnel air flowing through the background particulate filter under standard conditions;
is the particulate mass from the dilution air, or the dilution tunnel background air, as determined by the one of the methods described in paragraph 2.1.3.1. of Sub-Annex 6;
is the dilution factor determined in paragraph 3.2.1.1.1. of this Sub-Annex.
Where application of a background correction results in a negative result, it shall be considered to be zero mg/km.