Division 3.2.4.5.2 The break-off criterion for the charge-depleting Type 1 test is reached when the relative electric energy change REECi as calculated using the following equation, is less than 0.04.
where:
REECi ΔEREESS,i Ecycle i
is the relative electric energy change of the applicable test cycle considered i of the charge-depleting Type 1 test;
is the change of electric energy of all REESSs for the considered charge-depleting Type 1 test cycle i calculated according to paragraph 4.3. of this Sub-Annex, Wh;
is the cycle energy demand of the considered applicable WLTP test cycle calculated according to paragraph 5. of Sub-Annex 7, Ws;
is the index number for the considered applicable WLTP test cycle;
is a conversion factor to Wh for the cycle energy demand.