Division 4.4.2.1.1 The pure -electric range for the applicable WLTP test cycle PERWLTC for PEVs shall be calculated from the shortened Type 1 test as described in paragraph 3.4.4.2. of this Sub-Annex using the following equations:
where:
is the usable REESS energy determined from the beginning of the shortened Type 1 test procedure until the break-off criterion as defined in paragraph 3.4.4.2.3. of this Sub-Annex is reached, Wh;
is the weighted electric energy consumption for the applicable WLTP test cycle of DS1 and DS2 of the shortened Type 1 test procedure Type 1 test, Wh/km;
and
where:
is the electric energy change of all REESSs during DS1 of the shortened Type 1 test procedure, Wh;
is the electric energy change of all REESSs during DS2 of the shortened Type 1 test procedure, Wh;
is the electric energy change of all REESSs during CSSM of the shortened Type 1 test procedure, Wh;
is the electric energy change of all REESSs during CSSE of the shortened Type 1 test procedure, Wh;
and
where:
is the electric energy consumption for the applicable WLTP test cycle of DSj of the shortened Type 1 test procedure according to paragraph 4.3. of this Sub-Annex, Wh/km;
is the weighting factor for the applicable WLTP test cycle of DSj of the shortened Type 1 test procedure;
and
where:
is the weighting factor for the applicable WLTP test cycle of DSj of the shortened Type 1 test procedure;
is the electric energy change of all REESSs during the applicable WLTP test cycle from DS1 of the shortened Type 1 test procedure, Wh;