Division 4.4.2.2.3 The phase-specific pure electric-range PERp for PEVs shall be calculated from the Type 1 test as described in paragraph 3.4.4.1. of this Sub-Annex using the following equations:
where:
is the usable REESS energy according to paragraph 4.4.2.2.1. of this Sub-Annex, Wh;
is the electric energy consumption for the considered phase p determined from completely driven phases p of the consecutive cycle Type 1 test procedure, Wh/km;
and
where:
is the jth electric energy consumption for the considered phase p of the consecutive cycle Type 1 test procedure according to paragraph 4.3. of this Sub-Annex, Wh/km;
is the jth weighting factor for the considered phase p of the consecutive cycle Type 1 test procedure;
is the index number of the considered phase p;
is the whole number of complete WLTC phases p driven;
and
where:
is the electric energy change of all REESSs during the first driven phase p during the consecutive cycle Type 1 test procedure, Wh.