Division 4.4.2.2.2 The pure electric range for the WLTP city test cycle PERcity for PEVs shall be calculated from the Type 1 test as described in paragraph 3.4.4.1. of this Sub-Annex using the following equations:
where:
is the usable REESS energy according to paragraph 4.4.2.2.1. of this Sub-Annex, Wh;
is the electric energy consumption for the applicable WLTP city test cycle determined from completely driven applicable WLTP city test cycles of the consecutive cycle Type 1 test procedure, Wh/km;
and
where:
is the electric energy consumption for the applicable WLTP city test cycle j of the consecutive cycle Type 1 test procedure according to paragraph 4.3. of this Sub-Annex, Wh/km;
is the weighting factor for the applicable WLTP city test cycle j of the consecutive cycle Type 1 test procedure;
is the index number of the applicable WLTP city test cycle;
is the whole number of complete applicable WLTP city test cycles driven;
and
where:
is the electric energy change of all REESSs during the first applicable WLTP city test cycle of the consecutive cycle Type 1 test procedure, Wh.