OpenLegislation

Division 4.4.4.1 Determination of cycle-specific equivalent all-electric range

Original text. Later amendments are not shown.

The cycle-specific equivalent all-electric range shall be calculated using the following equation:

EAER=MCO2,CS− MCO2,CD,avgMCO2,CS×RCDC

where:

EAER
  • is the cycle-specific equivalent all-electric range, km;

  • MCO2,CS
  • is the charge-sustaining CO2 mass emission according to Table A8/5, step no. 7, g/km;

  • MCO2,CD,avg
  • is the arithmetic average charge-depleting CO2 mass emission according to the equation below, g/km;

  • RCDC
  • is the charge-depleting cycle range according to paragraph 4.4.2. of this Sub-Annex, km;

  • and

    MCO2,CD,avg=∑kj= 1MCO2,CD,j× dj∑kj= 1 dj

    where:

    MCO2,CD,avg
  • is the arithmetic average charge-depleting CO2 mass emission, g/km;

  • MCO2,CD,j
  • is the CO2 mass emission determined according to paragraph 3.2.1. of Sub-Annex 7 of phase j of the charge-depleting Type 1 test, g/km;

  • dj
  • is the distance driven in phase j of the charge-depleting Type 1 test, km;

  • j
  • is the index number of the considered phase;

  • k
  • is the number of phases driven up to the end of the transition cycle n according to paragraph 3.2.4.4 of this Sub-Annex.