OpenLegislation

Division 5.6.2 Interpolation family for NOVC-HEVs and OVC-HEVs

Original text. Later amendments are not shown.

In addition to the requirements of paragraph 5.6.1., only OVC-HEVs and NOVC-HEVs that are identical with respect to the following characteristics may be part of the same interpolation family:

  1. (a)

    Type and number of electric machines (construction type (asynchronous/ synchronous, etc..), type of coolant (air, liquid,) and any other characteristics having a non-negligible influence on CO2 mass emission and electric energy consumption under WLTP conditions;

  2. (b)

    Type of traction REESS (model, capacity, nominal voltage, nominal power, type of coolant (air, liquid));

  3. (c)

    F1Type of electric energy converter between the electric machine and traction REESS, between the traction REESS and low voltage power supply and between the recharge-plug-in and traction REESS, and any other characteristics having a non-negligible influence on CO 2 mass emission and electric energy consumption under WLTP conditions;

  4. (d)

    The difference between the number of charge-depleting cycles from the beginning of the test up to and including the transition cycle shall not be more than one.

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).