The following system requirements shall be met by a single torque meter by calibration:
- i..
Non linearity: < ± 6 Nm
- ii..
Repeatability: < ± 6 Nm
- iii..
Crosstalk: < ± 1 % FSO (only applicable for rim torque meters)
- iv..
Measurement rate: ≥ 20 Hz
where:
-
‘Non linearity’ means the maximum deviation between ideal and actual output signal characteristics in relation to the measurand in a specific measuring range.
-
‘Repeatability’ means closeness of the agreement between the results of successive measurements of the same measurand carried out under the same conditions of measurement.
-
‘Crosstalk’ means signal at the main output of a sensor (My), produced by a measurand (Fz) acting on the sensor, which is different from the measurand assigned to this output. Coordinate system assignment is defined according to ISO 4130.
-
‘FSO’ means full scale output of calibrated range.
The recorded torque data shall be corrected for the instrument error determined by the supplier.