The anemometer shall be calibrated in facility according to ISO 16622. The accuracy requirements according to Table 1 have to be fulfilled:

Table 1

Anemometer accuracy requirements

Air speed range[m/s]Accuracy air speed[m/s]Accuracy yaw angle in yaw angle range of 180 ± 7 degrees[degrees]
20 ± 1 ± 0,7± 1,0
27 ± 1 ± 0,9± 1,0
35 ± 1 ± 1,2± 1,0