Division 8.1.8.5.4 Preparation of the HC sampling system for the propane check
United Kingdom
F1Vacuum side leak check verification of the HC sampling system may be performed in accordance with point (g). If this procedure is used, the HC contamination procedure set out in point 7.3.1.3 may be used. If the vacuum side leak check is not performed according to paragraph (g), then the HC sampling system shall be zeroed, spanned, and verified for contamination, as follows:
- (a)
The lowest HC analyzer range that can measure the C3H8 concentration expected for the CVS and C3H8 flow rates shall be selected;
- (b)
The HC analyzer shall be zeroed using zero air introduced at the analyzer port;
- (c)
The HC analyzer shall be spanned using C3H8 span gas introduced at the analyzer port;
- (d)
Zero air shall be overflowed at the HC probe or into a fitting between the HC probe and the transfer line;
- (e)
The stable HC concentration of the HC sampling system shall be measured as overflow zero air flows. For batch HC measurement, the batch container (such as a bag) shall be filled and the HC overflow concentration measured;
- (f)
If the overflow HC concentration exceeds 2 μmol/mol, the procedure may not be advanced until contamination is eliminated. The source of the contamination shall be determined and corrective action taken, such as cleaning the system or replacing contaminated portions;
- (g)
When the overflow HC concentration does not exceed 2 μmol/mol, this value shall be recorded as x HCinit and it shall be used to correct for HC contamination as described in section 2 of Annex VII (mass based approach) or section 3 of Annex VII (molar based approach).