  1. (a)

    The propane check shall be performed as follows:

    1. (i)

      For batch HC sampling, clean storage media, such as evacuated bags shall be connected;

    2. (ii)

      HC measurement instruments shall be operated according to the instrument manufacturer's instructions;

    3. (iii)

      If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;

    4. (iv)

      Any integrating devices shall be zeroed;

    5. (v)

      Sampling shall begin and any flow integrators shall be started;

    6. (vi)

      C3H8 shall be released at the rate selected. If a reference flow rate of C3H8 is used, the integration of this flow rate shall be started;

    7. (vii)

      C3H8 shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;

    8. (viii)

      The C3H8 cylinder shall be shut off and sampling shall continue until it has been accounted for time delays due to sample transport and analyzer response;

    9. (ix)

      Sampling shall be stopped and any integrators shall be stopped;

  2. (b)

    In case the metering with a critical flow orifice is used, the following procedure may be used for the propane check as the alternative method of point 8.1.8.5.5(a);

    1. (i)

      For batch HC sampling, clean storage media, such as evacuated bags shall be connected;

    2. (ii)

      HC measurement instruments shall be operated according to the instrument manufacturer's instructions;

    3. (iii)

      If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;

    4. (iv)

      Any integrating devices shall be zeroed;

    5. (v)

      The contents of the C3H8 reference cylinder shall be released at the rate selected;

    6. (vi)

      Sampling shall begin, and any flow integrators started after confirming that HC concentration is to be stable;

    7. (vii)

      The cylinder's contents shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;

    8. (viii)

      Any integrators shall be stopped;

    9. (ix)

      The C3H8 reference cylinder shall be shut off.