Division 8.1.8.5.6 Evaluation of the propane check
United Kingdom
Post-test procedure shall be performed as follows:
- (a)
If batch sampling has been used, batch samples shall be analyzed as soon as practical;
- (b)
After analyzing HC, contamination and background shall be corrected for;
- (c)
Total C3H8 mass based on the CVS and HC data shall be calculated as described in Annex VII, using the molar mass of C3H8, M C3H8, instead of the effective molar mass of HC, M HC;
- (d)
If a reference mass (gravimetric technique) is used, the cylinder's propane mass shall be determined within ± 0,5 % and the C3H8 reference mass shall be determined by subtracting the empty cylinder propane mass from the full cylinder propane mass. If a critical flow orifice (metering with a critical flow orifice) is used, the propane mass shall be determined as flow rate multiplied by the test time;
- (e)
The reference C3H8 mass shall be subtracted from the calculated mass. If this difference is within ± 3,0 % of the reference mass, the CVS passes this verification.