A sampling system shall be tested for low-flow leaks as follows:
- (a)
The probe end of the system shall be sealed by taking one of the following steps:
- (i)
The end of the sample probe shall be capped or plugged;
- (ii)
The transfer line shall be disconnected at the probe and the transfer line capped or plugged;
- (iii)
A leak-tight valve in-line between a probe and transfer line shall be closed;
- (i)
- (b)
All vacuum pumps shall be operated. After stabilizing, it shall be verified that the flow through the vacuum-side of the sampling system is less than 0,5 % of the system's normal in-use flow rate. Typical analyzer and bypass flows may be estimated as an approximation of the system's normal in-use flow rate.