Division 1 The technical documentation referred to in point 1(d) of Article 3 shall include:
United Kingdom
- (a)
the name and address of the supplier;
- (b)
supplier’s model identifier;
- (c)
the model identifier of all equivalent models already placed on the market;
- (d)
identification and signature of the person empowered to bind the supplier;
- (e)
the declared and measured values for the following technical parameters:
- (1)
useful luminous flux (Φuse) in lm;
- (2)
colour rendering index (CRI);
- (3)
on-mode power (Pon) in W;
- (4)
beam angle in degrees for directional light sources (DLS);
- (5)
correlated colour temperature (CCT) in K for FL and HID light sources;
- (6)
'standby power (Psb) in W, including when it is zero;
- (7)
networked standby power (Pnet) in W for connected light sources (CLS);
- (8)
displacement factor (cos φ1) for LED and OLED mains light sources;
- (9)
colour consistency in MacAdam ellipse steps for LED and OLED light sources;
- (10)
luminance-HLLS in cd/mm2 (only for HLLS)
- (11)
flicker metric (PstLM) for LED and OLED light sources;
- (12)
stroboscopic effect metric (SVM) for LED and OLED light sources;
- (13)
excitation purity, only for CTLS, for the following colours and dominant wavelength within the given range:
Colour BlueDominant wave-length range
Green440 nm — 490 nm
Red520 nm — 570 nm
610 nm — 670 nm
- (1)
- (f)
the calculations performed with the parameters, including the determination of the energy efficiency class;
- (g)
references to the harmonised standards applied or other standards used;
- (h)
testing conditions if not described sufficiently in point (g);
- (i)
the reference control settings, and instructions on how they can be implemented, where applicable;
- (j)
instructions on how to remove lighting control parts and/or non-lighting parts, if any, or how to switch them off or minimise their power consumption during light source testing;
- (k)
specific precautions that shall be taken when the model is assembled, installed, maintained or tested.