The model shall be tested for each end user selectable signal input interface type which has specified that it can carry power management control signals or data. Where there are two or more identical signal interfaces not labelled for a specific host product type (e.g. HDMI-1, HDMI-2, etc.) it is sufficient to test one of these signal interfaces selected at random. Where there are labelled or menu designated signal interfaces (e.g. computer, set top box or analogous) the appropriate host signal source device should be connected to the designated signal interface for the test. The model shall be considered to comply with the applicable requirement if no signal by any input source is detected and the model switches into standby mode, off mode or networked standby mode.