Regulation 30 Room-sealed appliancesI1
Northern Ireland Not yet in force
A person shall not install a gas appliance in a room used or intended to be used as a bathroom or a shower room unless it is a room-sealed appliance.
A person shall not install a gas fire, other gas space heater or a gas water heater of more than 14 kilowatt heat input in a room used or intended to be used as sleeping accommodation unless the appliance is a room-sealed appliance.
A person shall not install a gas fire, other gas space heater or a gas water heater of 14 kilowatt heat input or less in a room used or intended to be used as sleeping accommodation unless—
it is a room-sealed appliance; or
it incorporates a safety control designed to shut down the appliance before there is a build up of a dangerous quantity of the products of combustion in the room concerned.
Annotations
Commencement
- I1
Reg. 30 in operation at 12.5.1997, see reg. 1