Paragraph 1.1 The flowrate rangeF1
The flowrate ran ge is subject to the following conditions:
(i)
the flowrate range of a measuring system shall be within the flowrate range of each of its elements, in particular the meter.
(ii)
meter and measuring system:
Table 1
| Specific measuring system | Characteristic of liquid | Minimum ratio of Qmax: Qmin |
|---|---|---|
| Fuel dispensers | Not Liquefied gases | 10: 1 |
| Liquefied gases | 5: 1 | |
| Measuring system | Cryogenic liquids | 5: 1 |
| Measuring systems on pipeline and systems for loading ships | All liquids | Suitable for use |
| All other measuring systems | All liquids | 4: 1 |
Annotations
Textual amendments
- F1
Schs. 1A-1K inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 27 para. 49 (with Sch. 27 para. 50(a)) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)