OpenLegislation

Paragraph 2.4.1 F1

For minimum measured quantities greater than or equal to 2 litres the following conditions apply:

Condition 1

Emin shall fulfil the condition: Emin ≥ 2 R, where R is the smallest scale interval of the indication device.

Condition 2

Emin is given by the formula: Emin = (2MMQ)x (A/100) where:

  • — MMQ is the minimum measured quantity,

  • — A is the numerical value specified in line A of Table 2.

Annotations

Textual amendments

F1

Schs. 1A-1K inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 27 para. 49 (with Sch. 27 para. 50(a)) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)