OpenLegislation

Paragraph 2.1 F1

MPE Category Y instruments

Table 1

Net Load (m) in verification scale intervals (e)Maximum permissible mean errorMaximum permissible error
Y(I)Y(II)Y(a)Y(b)StaticAutomatic
0 < m ≤ 50,0000 < m ≤ 5,0000 < m ≤ 5000 < m ≤ 50± 0.5 e± 1 e
50,000 < m ≤ 200,0005,000 < m ≤ 20,000500 < m ≤ 2,00050 < m ≤ 200± 1.0 e± 1.5 e
200,000 < m20,000 < m ≤ 100,0002,000 < m ≤ 10,000200 < m ≤ 1,000± 1.5± 2 e

Annotations

Textual amendments

F1

Schs. 1A-1K inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 27 para. 49 (with Sch. 27 para. 50(a)) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)