Paragraph 2.2 Verification scale interval — single interval instrumentsF1
Table 2
| Accuracy classes | Verification scale interval | Number of verification scale intervalsn = Max/e | ||
|---|---|---|---|---|
| Minimum | Maximum | |||
| Minimum | Maximum | |||
| XI | Y(I) | 0.001 g ≤ e | 50,000 | |
| XII | Y(II) | 0.001 g ≤ e ≤ 0.05 g | 100 | 100,000 |
| 0.1 g ≤ e | 5,000 | 100,000 | ||
| XIII | Y(a) | 0.1 g ≤ e ≤ 2 g | 100 | 10,000 |
| 5 g ≤ e | 500 | 10,000 | ||
| XIIII | Y(b) | 5 g ≤ e | 100 | 1,000 |
Annotations
Textual amendments
- F1
Schs. 1A-1K inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 27 para. 49 (with Sch. 27 para. 50(a)) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)