United Kingdom

Table AL5 - ALs for contact currents

Frequency of electromagnetic field in which an object is presentContact current ALs (Ic)[mA]
up to 2.5 kHz1.0
2.5 ≤ f < 100 kHz0.4 f
100 ≤ f ≤ 10,000 kHz40

NOTES

1

“f” is the frequency expressed in kHz.

2

The ALs are root mean square values.

3

The ALs represent the maximum steady state current created during a continuous contact with an object in an electromagnetic field.

Table AL6 – ALs for static magnetic fields

Potential indirect effectMagnetic flux density ALs (B0)[mT]
Interference with active implanted medical devices0.5
Attraction and projectile risk in the fringe field of high field strength sources (> 100 mT)3

NOTE

The AL for interference with active implanted medical devices represents the maximum field value at any place where a worker may be working.