Chapter Action levels – non-thermal effects
United Kingdom
Table AL5 - ALs for contact currents
| Frequency of electromagnetic field in which an object is present | Contact current ALs (Ic)[mA] |
|---|---|
| up to 2.5 kHz | 1.0 |
| 2.5 ≤ f < 100 kHz | 0.4 f |
| 100 ≤ f ≤ 10,000 kHz | 40 |
NOTES
1
“f” is the frequency expressed in kHz.
2
The ALs are root mean square values.
3
The ALs represent the maximum steady state current created during a continuous contact with an object in an electromagnetic field.
Table AL6 – ALs for static magnetic fields
| Potential indirect effect | Magnetic flux density ALs (B0)[mT] |
|---|---|
| Interference with active implanted medical devices | 0.5 |
| Attraction and projectile risk in the fringe field of high field strength sources (> 100 mT) | 3 |
NOTE
The AL for interference with active implanted medical devices represents the maximum field value at any place where a worker may be working.
Notes on Part 3
Commencement
- I1
Sch. Pt. 3 in force at 21.11.2016, see reg. 1