OpenLegislation

Paragraph 10 Design parametersI1

England and Wales

(1)

The authorised scheme must be constructed in accordance with the parameters assessed in the environmental statement and set out in Table 2.

(2)

The F1undertaker may not undertake Work No. 1 in a manner which would give rise to any materially new or materially different environmental effects to those identified in the environmental statement based upon the maximum design scenarios set out in Table 3.5 of the environmental statement.

(3)

References to the location of an offshore surface structure in Table 2 is a reference to the centre point of that structure.

Table 2

ParameterValue
Maximum number of wind turbine generators96
Maximum height of wind turbine generators when measured from LAT to the tip of the vertical blade (m)364
Maximum rotor diameter of each wind turbine generator (m)320
Maximum rotor swept area (m2) 5,468,884
Minimum distance from LAT to the lowest point of the rotating blade for each turbine (m)34
Minimum distance from HAT to the lowest point of the rotating blade for each turbine (m)26
Minimum distance between offshore surface structures (in all directions) (m)1,400
Maximum diameter of pin-piles for wind turbine generators on jacket pin-pile foundations (m)5.5
Maximum diameter of gravity base at the seabed for wind turbine generators on gravity base foundations (m)49
Maximum diameter of buckets for wind turbine generators on suction bucket jackets (m)18
Maximum diameter of pin-piles for offshore substation platforms on jacket pin-pile foundations (m)5.5
Maximum diameter of gravity base at the seabed for offshore substation platforms on gravity base foundations (m)80
Maximum diameter of buckets for offshore substation platforms on suction bucket jackets (m)18
Maximum number of wind turbines on jacket driven pin-pile foundations64
Maximum volume of extracted seabed material to be used in gravity base foundations (m3) 490,000
Maximum total seabed footprint of wind turbine generators (including scour protection) (m2) 735,488
Maximum volume of scour protection for wind turbine generators (m3)1,701,998
Maximum volume of scour protection for offshore substation foundations (m3)58,361
Maximum number of offshore substation platforms4
Maximum dimensions of offshore substations (excluding towers, helipads, masts, and cranes):
Height when measured from LAT (m)70
Length (m)80
Width (m)60
Maximum total seabed footprint area for offshore substation foundations (including scour protection) (m2) 24,964
Maximum total length of cables (inter-array and interconnector) (km)450
Maximum number of cable crossings (inter-array and interconnector)20
Maximum volume of cable protection (inter-array and interconnector) (m3) 852,600
Maximum total seabed footprint area for cable protection (m2) 548,800

Annotations

Textual amendments

F1

Words in Sch. 3 para. 10(2) substituted (9.4.2026) by The Morgan Offshore Wind Project Generation Assets (Correction) Order 2026 (S.I. 2026/441), art. 1, Sch.

Commencement

I1

Sch. 3 para. 10 in force at 22.9.2025, see art. 1