OpenLegislation

Paragraph 20 Construction, Operation and MaintenanceI1

England, Wales and Scotland

(1)

Vibratory or drilled “pin” piling must be used as standard, with percussive piling only used if required to drive a pile to its design depth and where the relevant undertaker has established, following the carrying out of a desk top study informed by appropriate survey information, that vibratory or drilled “pin” piling would be ineffective.

(2)

Where percussive piling is established to be necessary in accordance with sub-paragraph (1)—

(a)

soft-start procedures must be used to ensure incremental increase in pile power over a set time period until full operational power is achieved;

(b)

the soft-start duration must be a period of not less than 20 minutes; and

(c)

should piling cease for a period greater than 10 minutes, then the soft start procedure must be repeated.

Annotations

Commencement

I1

Sch. 11 para. 20 in force at 11.3.2024, see art. 1