OpenLegislation

Paragraph

F1Type of equipment

Net installed power P (in kW)

Electric power Pelf1 in kW

Mass of appliance m in kg

Cutting width L in cm

Permissible sound power level in dB/1 pW
Stage I as from 3 January 2002Stage II as from 3 January 2006
a

Pel for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. Pel for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2.

b

For the following types of equipment the figures for Stage I shall continue to apply for Stage II—

  • Walk-behind vibrating rollers;

  • Vibratory plates (>3 kW);

  • Vibratory rammers;

  • Dozers (steel tracked);

  • Loaders (steel tracked >55 kW);

  • Combustion-engine driver counterbalanced lift trucks;

  • Compacting screed paver-finishers; and

  • Hand-held internal combustion-engine concrete-breakers and picks (15< m<30).

c

For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply.

Compaction machines (vibrating rollers, vibratory plates, vibratory rammers) P ≤ £ 8108105f2
8 < P ≤ £70109106
P > 7089 + 11 1g P86 + 11 1g P
Tracked dozers, tracked loaders, tracked excavator-loaders P ≤ 55106103
P > 5587 + 11 1g P84 + 11 1g P
Wheeled dozers,wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, compaction machines (non-vibrating rollers),paver-finishers, hydraulic power packs P ≤ 55104101
P > 5585 + 11 1g P82 + 11 1g P
Mobile cranesP ≤ 55104101f3
P > 5585 + 11 1g P82 + 11 1g P 101
Excavators, builders' hoists for the transport of goods, construction winches, motor hoes P ≤ 159693
P > 1583 + 11 1g P80 + 11 1g P
Hand-held concrete-breakers and picks m ≤ 15107105
15< m < 3094 + 11 1g m92 + 11 1g m
m ≥ 3096 + 11 1g m94 + 11 1g m
Tower cranes98 + 1g P96 + 1g P
Welding and power generatorsPel ≤ 297 + 1g Pel95 + 1g Pel
2 < Pel ≤ 1098 + 1g Pel96 + 1g Pel
10 > Pel97 + 1g Pel95 + 1g Pel
CompressorsP ≤ 159997
P > 1597 + 2 1g Pel95 + 2 1g Pel
Lawnmowers, lawn trimmers/lawn-edge trimmers L ≤ 509696
50 < L ≤ 7010098
70 < L ≤ 120100100
L > 120105105
The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0.5, use lower number; greater than or equal to 0.5, use higher number).

Annotations

Textual amendments

F1

Sch. 3 Table substituted (3.1.2006) by The Noise Emission in the Environment by Equipment for Use Outdoors (Amendment) Regulations 2005 (S.I. 2005/3525), regs. 1, 2, Sch.

Footnotes

f1

a

Pel for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. Pel for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2.

f2

b

For the following types of equipment the figures for Stage I shall continue to apply for Stage II—

  • Walk-behind vibrating rollers;

  • Vibratory plates (>3 kW);

  • Vibratory rammers;

  • Dozers (steel tracked);

  • Loaders (steel tracked >55 kW);

  • Combustion-engine driver counterbalanced lift trucks;

  • Compacting screed paver-finishers; and

  • Hand-held internal combustion-engine concrete-breakers and picks (15< m<30).

f3

c

For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply.

Notes on the whole SI

Textual amendments

F1

S.I. 2000/3238.

F2

1972 c. 68.

Notes on Schedule 3

Textual amendments

F1

Words in Sch. 3 heading inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 8 para. 17 (with Sch. 8 para. 14) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)