Appendix 3
DATA EVALUATION AND CALCULATIONS
Gaseous emissions data evaluation
For the evaluation of the gaseous emissions, the chart reading of the last 60 seconds of each mode shall be averaged, and the average concentrations (conc) of HC, CO, NOX and CO2 if the carbon balance method is used, during each mode shall be determined from the average chart readings and the corresponding calibration data. A different type of recording can be used if it ensures an equivalent data acquisition.
The average background concentrations (concd) may be determined from the bag readings of the dilution air or from the continuous (non-bag) background reading and the corresponding calibration data.
Particulate emissions
For the evaluation of the particulates, the total sample masses (MSAM,i) or volumes (VSAM,i) through the filters shall be recorded for each mode.
-
The filters shall be returned to the weighing chamber and conditioned for at least one hour, but not more than 80 hours, and then weighed. The gross weight of the filters shall be recorded and the tare weight (see section 3.1, Annex III) subtracted. The particulate mass (Mf for the single filter method; Mf,i for the multiple filter method) is the sum of the particulate masses collected on the primary and back-up filters.
-
If background correction is to be applied, the dilution air mass (MDIL) or volume (VDIL) through the filters and the particulate mass (Md) shall be recorded. If more than one measurement was made, the quotient Md/MDIL or Md/VDILmust be calculated for each single measurement and the values averaged.
Calculation of the gaseous emissions
The finally reported test results shall be derived through the following steps:
Determination of the exhaust gas flow
The exhaust gas flow rate (GEXHW, VEXHW, or VEXHD) shall be determined for each mode according to Annex III, Appendix 1, sections 1.2.1 to 1.2.3.
When using a full flow dilution system, the total dilute exhaust gas flow rate (GTOTW, VTOTW) shall be determined for each mode according to Annex III, Appendix 1, section 1.2.4.
Dry/wet correction
When applying GEXHW, VEXHW, GTOTW, VTOTW, the measured concentration shall be converted to a wet basis according to the following formulae, if not already measured on a wet basis:
-
For the raw exhaust gas:
-
or:
-
For the diluted exhaust gas:
-
or:
-
FFHmay be calculated by:
-
For the dilution air:
-
For the intake air (if different from the dilution air):
-
where:
Ha: absolute humidity of the intake air, g water per kg dry air Hd: absolute humidity of the dilution air, g water per kg dry air Rd: relative humidity of the dilution air, % Ra: relative humidity of the intake air, % pd: saturation vapour pressure of the dilution air, kPa pa: saturation vapour pressure of the intake air, kPa pB: total barometric pressure, kPa
Humidity correction for NOX
As the NOX emission depends on ambient air conditions, the NOX concentration shall be corrected for ambient air temperature and humidity by the factor KHgiven in the following formula:
-
where:
A: 0.309 GFUEL/GAIRD −0.0266 B: −0.209 GFUEL/GAIRD+ 0.00954 T: temperatures of the air in K
Ha: humidity of the intake air, g water per kg dry air;
Ra: relative humidity of the intake air, % pa: saturation vapour pressure of the intake air, kPa pb: total barometric pressure, kPa
Calculation of emission mass flow rates
The emission mass flow rates for each mode shall be calculated as follows:
For the raw exhaust gasf1
or:
or:
For the dilute exhaust gas
or:
where:
concis the background corrected concentration
conc − concd × (1 − (1/DF))
or:
The coefficients u – wet, v – dry, w – wet shall be used according to the following table:
-
Gas u v w conc NOX 0.001587 0.002053 0.002053 ppm CO 0.000966 0.00125 0.00125 ppm HC 0.000479 — 0.000619 ppm CO2 15.19 19.64 19.64 percent -
The density of HC is based upon an average carbon to hydrogen ratio of 1:1.85.
Calculation of the specific emissions
The specific emission (g/kWh) shall be calculated for all individual components in the following way:
-
where Pi = Pm,i + PAE,i.
-
The weighting factors and the number of modes (n) used in the above calculation are according to Annex III, section 3.6.1.
Calculation of the particulate emission
The particulate emission shall be calculated in the following way:
Humidity correction factor for particulates
As the particulate emission of diesel engines depends on ambient air conditions, the particulate mass flow rate shall be corrected for ambient air humidity with the factor Kp given in the following formula:
-
Ha: humidity of the intake air, grammes of water per kg dry air;
-
Ra: relative humidity of the intake air, %;
-
Pa: saturation vapour pressure of the intake air, kPa;
-
Pb: total barometric pressure, kPa.
Partial flow dilution system
The final reported test of the particulate emission shall be derived through the following steps. Since various types of dilution rate control may be used, different calculation methods for equivalent diluted exhaust gas flow rate GEDF or equivalent diluted exhaust gas volume flow rate VEDF apply. All calculations shall be based upon the average values of the individual modes (i) during the sampling period.
Isokinetic systems
-
or:
-
or:
-
Where r corresponds to the ratio of the cross sectional areas of the isokinetic probe Ap and exhaust pipe AT:
Systems with measurement of CO2 or NOX concentration
-
or
-
where:
-
ConcE = wet concentration of the tracer gas in raw exhaust
-
ConcD = wet concentration of the tracer gas in the diluted exhaust
-
Conca = wet concentration of the tracer gas in the dilution air
-
Concentrations measured on a dry basis shall be converted to a wet basis according to section 1.3.2. of this Appendix.
Systems with CO2 measurement and carbon balance method
-
where:
-
CO2D = CO2 concentration of the diluted exhaust
-
CO2a = CO2 concentration of the dilution air
-
(concentrations in volume % on wet basis)
-
This equation is based upon the carbon balance assumption (carbon atoms supplied to the engine are emitted as CO2) and derived through the following steps:
-
and:
Systems with flow measurement
Full flow dilution system
The final reported test results of the particulate emission shall be derived through the following steps.
-
All calculations shall be based upon the average values of the individual modes (i) during the sampling period.
-
or:
Calculation of the particulate mass flow rate
The particulate mass flow rate shall be calculated as follows:
-
For the single filter method:
-
or:
-
where:
-
(GEDFW)aver, (VEDFW)aver, (MSAM)aver, (VSAM)aver over the test cycle shall be determined by summation of the average values of the individual modes during the sampling period:
-
-
-
where i=1, … n
-
-
For the multiple filter method:
-
or:
-
-
where i=l, … n
-
-
The particulate mass flow rate may be background corrected as follows:
-
For single filter method:
-
or:
-
If more than one measurement is made, (Md/MDIL) or (Md/VDIL) shall be replaced with (Md/MDIL)aver or (Md/VDIL)aver, respectively.
-
For multiple filter method:
-
or:
-
If more than one measurement is made, (Md/MDIL) or (Md/VDIL) shall be replaced with (Md/MDIL)aver or (Md/VDIL)aver, respectively.
-
or;
Calculation of the specific emissions
The specific emission of particulates PT (g/kWh) shall be calculated in the following wayf2
For the single filter method:
For the multiple filter method:
Effective weighting factor
For the single filter method, the effective weighting factor WFE,i for each mode shall be calculated in the following way:
-
or:
-
-
where i=l, … n.
-
-
The value of the effective weighting factors shall be within ± 0.005 (absolute value) of the weighting factors listed in Annex III, section 3.6.1.
Annotations
Footnotes
- f1
-
In the case of NOX, the NOX concentration (NOXconc or NOXconcc) has to be multiplied by KHNOX(humidity correction factor for NOX quoted in the previous section 1.3.3) as follows:
KHNOX× conc or KHNOX× conc.
- f2
-
The particulate mass flow rate PTmass has to be multiplied by Kp (humidity correction factor for particulates quoted in section 1.4.1).