OpenLegislation

Paragraph 5 Detailed offshore design parametersI1

England and Wales

(1)

The total length of cables must not exceed 1,190 kilometres and the total length of cable trench within which the cables will be placed must not exceed 910 kilometres;

(2)

The total volume of cable protection must not exceed 308,236m3

(3)

The total area occupied by cable protection must not exceed 586,086m2; and

(4)

The length of cables and volume and area of cable protection must not exceed the individual distributions set out in Table 2 of the outline scour protection and cable protection plan and must not exceed the following parameters in respect of the corresponding Work Nos.—

WorkLengthCable protection (m3)Cable protection (m2)
Work No. 1(e and f) (array)600 kilometres198,500 m3389,000 m2
Work No. 3A (interconnector link)90 kilometres17,000 m334,000 m2
Work No. 3B (project interconnector)180 kilometres41,000 m374,000 m2
Work No. 4A and 4B (export cable)500 kilometres69,236m3124,086m2
(5)

In the event of scenario 1, the undertaker may commence either Work No. 3A or Work No. 3B and, for the avoidance of doubt, must not commence both of Work No. 3A and Work No. 3B.

Annotations

Commencement

I1

Sch. 1 Pt. 3 para. 5 in force at 1.1.2022, see art. 1