Paragraph 3 Parameters of authorised developmentI1
England and Wales
(1)
The elements of the authorised development listed in column (1) of the table below (design parameters) must not exceed the maximum dimensions and levels and, where applicable, the minimum dimensions, set out in relation to that element in columns (3) to (7) of that table.
Table 1
| (1) Element of authorised development | (2) Work No. | (3) Maximum length (metres) | (4) Maximum width (metres) | (5) Maximum height (metres) AOD | (6) Minimum height (metres) above surrounding ground level | (7) Maximum depth (metres) below AOD |
|---|---|---|---|---|---|---|
| Main Riverside Energy Park Building | 1A (excluding Work No.1A(iv), 1C and 1E | 200 | 102 | 65 | – | – |
| Solid fuel storage bunker | Part of Work No. 1A(i) | – | – | – | – | 8 |
| Anaerobic digestion system | 1B (excluding Work No. 1B(vi) and Work No. 1B(vii) | 87 | 68 | 43 | – | – |
| Other integral process buildings and structures | 1D, 2(b), 3, 4, 5, 6 and 7 | 111 | 116 | 38 | – | – |
| Emissions stacks(s) | 1A(iv) | – | 46 | 113 | 90 | – |
| Emission stack | 1B(vi) | 11 | 8 | |||
| Gas Flare | 1B(vii) | 17 | 4 |
(2)
The above surrounding ground level in respect of Work No. 1 must comply with the following parameters: a minimum level of one metre AOD and maximum level of three metres AOD.
Annotations
Commencement
- I1
Sch. 2 para. 3 in force at 1.5.2020, see art. 1