OpenLegislation

The Weighing Equipment (Filling and Discontinuous Totalisting Automatic Weighing Machines) Regulations 1986 in Northern Ireland

S.I. 1986/1320 · Made 25 July 1986 · Extends to United Kingdom

Original text. legislation.gov.uk does not revise statutory instruments, so later amendments are not shown here. Changes made to it are listed under each provision when known.

WEIGHTS AND MEASURES

Made 25th July 1986

Laid before Parliament 8th August 1986

Coming into Operation 1st September 1986

The Secretary of State, in exercise of the powers conferred by sections 11(1), (4) and (7), 12(12), 15(1), 86(1) and 94(1) of the Weights and Measures Act 1985 and of all other powers enabling him in that behalf, hereby makes the following Regulations:—C1

Annotations to the whole text

Modifications

C1

Regulations disapplied (17.7.2000) by The Weighing Equipment (Automatic Gravimetric Filling Instruments) Regulations 2000 (S.I. 2000/388), reg. 1(1)(2) (with regs. 3, 4)

Contents

  1. 23AFilling Machines imported from a member State or an EEA State
  2. 32ADiscontinuous totalisers imported from a member State or an EEA State
  3. Schedule 2: DISCONTINUOUS TOTALISERS
  4. Part I: testing— general requirements
  5. 1Paragraph 1
  6. 2Paragraph 2
  7. 3Paragraph 3
  8. 4Paragraph 4
  9. 5Paragraph 5
  10. Part II: testing— using a separate non-automatic weighing machine
  11. 6Paragraph 6
  12. Part III: testing—using an internal non-automatic weighing facility
  13. 7Paragraph 7
  14. 8Paragraph 8
  15. FILLING MACHINES
  16. DISCONTINUOUS TOTALISERS
  17. Explanatory note

23AFilling Machines imported from a member State or an EEA StateF1F5

(1)

In relation to a filling machine imported into Great Britain from F2a member State or from an EEA State, subject to paragraph (4) below, an inspector shall not carry out any test in accordance with the foregoing provisions of this Part of these Regulations if, together with the filling machine being imported, he is presented with the requisite documentation.

(2)

In this regulation and in regulation 34 below–

(a)

“requisite documentation” means–

(i)

the test report of an approved body that the filling machine which is the subject of that report has been tested on the same basis as those set out in this Part of these Regulations and stating which tests have been applied to it; and

(ii)

the test results relating to those tests; and

(b)

“EEA State” means a State which is a Contracting Party to the EEA Agreement F3...; and in this paragraph “the EEA Agreement” means the Agreement on the European Economic Area signed at Oporto on 2nd May 1992 as adjusted by the Protocol signed at Brussels on 17th March 1993.

(F43)

A body is an “approved body” for the purposes of this regulation if it is a body in a member State or in an EEA State which has responsibility in that State for metrological control of filling machines or is a laboratory which has been accredited for the purposes of testing filling machines in a member State or in an EEA State as being a body which conforms with the criteria set out in BS EN ISO/IEC 17025:2000.

(4)

Nothing in these Regulations shall prevent an inspector testing in accordance with the foregoing provisions of this Part of these Regulations where he is not satisfied–

(a)

as to the authenticity of the test report or the results presented to him; or

(b)

that the test results presented to him are results which in fact relate to the filling machine being imported; or

(c)

that the filling machine has not been dismantled after the tests to which the test report relates were carried out.

32ADiscontinuous totalisers imported from a member State or an EEA StateF1F5

(1)

In relation to discontinuous totalisers imported into Great Britain from F2a member State or from an EEA State, subject to paragraph (4) below, an inspector shall not carry out any test in accordance with the foregoing provisions of this Part of these Regulations if, together with the discontinuous totalisers being imported, he is presented with the requisite documentation.

(2)

In this regulation and in regulation 34 below—

(a)

“requisite documentation” means—

(i)

the test report of an approved body that the discontinuous totalisers which are the subject of that report have been tested on the same basis as those set out in this Part of these Regulations and stating which tests have been applied to them; and

(ii)

the test results relating to those tests; and

(b)

“EEA State” means a State which is a Contracting Party to the EEA Agreement F3...; and in this paragraph “the EEA Agreement” means the Agreement on the European Economic Area signed at Oporto on 2nd May 1992 as adjusted by the Protocol signed at Brussels on 17th March 1993.

(F43)

A body is an “approved body” for the purposes of this regulation if it is a body in a member State or in an EEA State which has responsibility in that State for metrological control of discontinuous totalisers or is a laboratory which has been accredited for the purposes of testing discontinuous totalisers in a member State or in an EEA State as being a body which conforms with the criteria set out in BS EN ISO/IEC 17025:2000.

(4)

Nothing in these Regulations shall prevent an inspector testing in accordance with the foregoing provisions of this Part of these Regulations where he is not satisfied—

(a)

as to the authenticity of the test report or the results presented to him; or

(b)

that the test results presented to him are results which in fact relate to the discontinuous totalisers being imported; or

(c)

that the discontinuous totalisers have not been dismantled after the tests to which the test report relates were carried out.

1F1

Discontinuous totalisers provided with a display of totalised weight only (to which, accordingly, the requirements of regulations 9 and 24 do not apply) shall be subject to material testing in accordance with Part II of this Schedule.

2F1

Discontinuous totalisers which embody the facilities referred to in regulation 9 but not those referred to in regulation 24 shall be subject to the requirements of regulation 32(2) in addition to the provisions of Part II of this Schedule.

3F1

Discontinuous totalisers to which regulations 9 and 24 are applicable may be tested in accordance wtih the provisions of Part III of this Schedule.

4F1

(1)

Subject to sub-paragraph (2) below, when testing a discontinuous totaliser, an inspector shall satisfy himself that—

(a)

it is properly balanced or set to zero when unloaded;

(b)

any beam or leverwork has sufficient room for oscillation and returns to the position of equilibrium when the load is removed; and

(c)

any indicator returns to the zero mark or given point when the load is removed.

(2)

Sub-paragraphs (1)(a) and (c) above shall not apply in the case of a discontinuous totaliser of a pattern in respect of which a certificate of approval is in force, if in the certificate of approval or the notice of examination in respect of that patttern it is described as not so constructed as to balance when unloaded.

5F1

Before commencing material testing of a discontinuous totaliser, the inspector shall satisfy himself that the arrangements (which may include the use of a non-automatic weighing machine or an internal non-automatic weighing facility) to be used for determining the weight of material used in the testing will give a weight determination of each test load (determined in one or more weighing operations) to an accuracy equal to or better than—

(a)

one-fifth of the prescribed limits of error for material testing; or

(b)

in a case where the accuracy of such arrangements is assessed immediately before use, one-third of such prescribed limits.

6F1

(1)

The tests specified in sub-paragraphs (2), (3) and (4) below shall be carried out on a discontinuous totaliser under normal conditions of use.

(2)

A minimum of three individual tests (including at least one at minimum load and at least one at maximum capacity) shall be carried out, each test involving the weighing of a quantity of suitable material as nearly as practicable equal to the minimum totalised load marked on the machine.

(3)

In the case only of a discontinuous totaliser first passed as fit for use for trade before 29th April 1996, and if the person submitting it for testing so requests, the test at maximum capacity under sub-paragraph (2) above may be made with twenty separate loads and the words “as nearly as practicable equal to the minimum totalised load marked on the machine” in that sub-paragraph shall not have effect.

(4)

Unless already included in the tests carried out under sub-paragraphs (2) and (3) above two further tests (which shall include at least five weighing cycles and a quantity of material not less than the minimum totalised load) shall be carried out, one at the minimum load and one at the maximum capacity.

(5)

For each of the tests carried out under sub-paragraphs (2), (3) and (4) above, the inspector shall determine—

(a)

the weight of material used in the test using the arrangements referred to in paragraph 5 above;

(b)

the material testing error by ascertaining the difference between the weight of the material determined in accordance with sub-paragraph (a) above and the value of the weight of the material obtained from the totalisation indicating device.

7F1

Where a discontinuous totaliser is constructed with an internal non-automatic weighing facility complying with regulations 9 and 24(1)(a) the machine may be tested by the use of that facility if the facility has first been tested by standard weights to verify that the weight indicating device (if necessary, in conjunction with a calibration chart or graph prepared from the results) will provide the accuracy required for the purposes of paragraph 5 above in the range required for the purposes of paragraph 8 below.

8F1

(1)

After the machine has weighed and discharged suitable material for at least five separate fillings of the load receptor by the normal automatic process, the process shall be stopped with the load receptor empty; and the inspector shall—

(a)

ensure that the individual weight indicating device is set to zero or a given point; and

(b)

set the totalisation indicating device to zero or record the indicated total.

(2)

The automatic process shall be restarted so that the load receptor is filled and automatically weighed; and before any material is discharged the process shall be interrupted and the inspector shall determine the individual weight value.

(3)

The automatic process shall be restarted so that the load receptor is discharged and automatically weighed; and before any further material is supplied to the load receptor the process shall be interrupted and the inspector shall determine the individual weight value.

(4)

From the weight values recorded in accordance with sub-paragraphs (2) and (3) above the inspector shall determine the true net weight of the material discharged taking account of any calibration chart or graph prepared for the purposes of paragraph 7 above.

(5)

The inspector shall then—

(a)

determine the total true net weight of a number of separate loads in accordance with sub-paragraphs (2), (3) and (4) above to complete material tests as specified in sub-paragraphs (6), (7) and (8) below under normal conditions of use; and

(b)

record the indication of the totalised weight of material in each test.

(6)

A minimum of three individual tests (including at least one at minimum load and at least one at maximum capacity) shall be carried out, each test involving the weighing of a quantity of suitable material as nearly as practicable equal to the minimum totalised load marked on the machine.

(7)

In the case only of a discontinuous totaliser first passed as fit for use for trade before 29th April 1996 and if the person submitting it for testing so requests, the test at maximum capacity under sub-paragraph (6) above may be carried out with twenty separate loads and the words “as nearly as practicable equal to the minimum totalised load” in that sub-paragraph shall not have effect.

(8)

Unless already included in the tests carried out under sub-paragraphs (6) and (7) above two further tests (which shall include at least five weighing cycles and a quantity of material not less than the minimum totalised load), shall be carried out, one at the minimum load and one at the maximum capacity.

(9)

For each group of tests referred to in sub-paragraph (5)(a) above, the inspector shall determine the material test error by ascertaining the difference between the weight of material determined as required by that sub-paragraph and the value of the weight of material obtained from the totalisation indicating device in accordance with sub-paragraphs (1)(b) and (5)(b) above.

FILLING MACHINES

TABLE 1

In relation to passing as fit for use for tradeIn relation to the obliteration of the stamp
Description of machineMaximum capacity of machinefor the purposes of test Afor the purposes of test Bfor the purposes of test Afor the purposes of test B
(1)(2)(3)(4)(5)(6)
Filing machines for use only for weighing potato crisps and other similar products commonly known as snack foodsany capacity20 per cent., in excess only, of the total purported weight of 20 test loads, and no error in deficiency of the purported weight of any of those test loads.Test not applicable20 per cent., in excess only, of the total purported weight of 20 test loads, and no error in deficiency of the purported weight of any of those test loadsTest not applicable
Filling machines for use only for weighing solid fuel110 kg or less
Filling machines for use only for weighing vegetable produce55 kg or less1 per cent., in excess only, of the purported weight of each test load1 per cent., in excess and no limit in deficiency, of the purported weight of each test load2 per cent., in excess only, of the purported weight of each test load2 per cent., in excess and no limit in deficiency, of the purported weight of each test load
All filling machines other than those described above in columns 1 and 2 of this Tableless than 5 kg
5 kg or more0.5 per cent., in excess or in deficiency, of the purported weight of each test loadTest not applicable1 per cent., in excess or in deficiency, of the purported weight of each test loadTest not applicable

DISCONTINUOUS TOTALISERSF1

Table 2

Class of accuracy of discontinuous totaliserLimits of error relative to weight of material used in tests
In relation to passing as fit for use for tradeIn relation to obliteration of the stamp
Class 0.2Plus or minus 0.1%Plus or minus 0.2%
Class 0.5Plus or minus 0.25%Plus or minus 0.5%
Class 1Plus or minus 0.5%Plus or minus 1%
Class 2Plus or minus 1%Plus or minus 2%

Explanatory note

The Regulations prescribe filling and discontinuous totalising automatic weighing machines for the purposes of section 11(1) of the Weights and Measures Act 1985, and exclude them from the application of the Weights and Measures Regulations 1963 (where they were formerly prescribed within the class of automatic weighing machines) except in so far as such machines are capable of also being used as a counter machine, platform weighing machine or a weighbridge.

The Regulations make provision as to:

  1. (a)

    the purposes for which such automatic weighing machines may be used for trade (Regulation 4);

  2. (b)

    the materials and principles of construction of them and their marking (Regulations 5 to 18, 24 and 25);

  3. (c)

    the manner of erection and use of them for trade (Regulations 19 to 21 and 26 to 30);

  4. (d)

    their testing, passing as fit for use for trade and stamping and the obliteration of such stamps (Regulations 22, 23, 31, 32, and 34 to 40 and Schedules 1 and 2);

  5. (e)

    the prescribed limits of error (Regulation 33 and Schedule 3).

The Regulations make the following changes of substance:—

  1. (a)

    a requirement has been included to ensure that automatic weighing machines shall not be used for trade below specified minimum loads or above their maximum capacity (Regulation 4);

  2. (b)

    a requirement has been included to limit the range of adjustment of any zero-setting devices of automatic weighing machines designed to compensate for the wear and tear of ordinary use in trade (Regulation 8);

  3. (c)

    a requirement has been included to provide facilities for easy and practicable weighings, for test purposes, on automatic weighing machines where visual indication of individual weighings is incorporated (Regulation 9);

  4. (d )

    there are new requirements for the principles of construction and marking for filling machines (Regulations 14 to 17);

  5. (e)

    there are new requirement for the manner of erection and use for trade of filling machines (Regulations 19 to 21);

  6. (f )

    a requirement has been included to ensure that filling machines intended to be permanently installed and discontinuous totalisers shall be completely erected on site before being tested, passed as fit for use for trade and stamped (Regulations 22(2) and 31(1));

  7. (g )

    a requirement has been included to ensure that the inspector testing any automatic weighing machines must, if he so requests, be provided with the appropriate test material (Regulations 22(3) and 31(3));

  8. (h )

    a requirement has been included to ensure that all installations of discontinuous totalisers have provisions for the depositing and collection of test material in a reliable and easy manner (Regulation 26(1));

  9. (i)

    a requirement has been included to ensure that a non-automatic weighing machine is available for use, where necessary, in the vicinity of any discontinuous totaliser used for trade (Regulation 26(2));

  10. (j)

    a requirement has been included to ensure that access is provided for cleaning of discontinuous totalisers (Regulation 28(2));

  11. (k)

    the grounds on which an inspector may obliterate the stamp on automatic weighing machines have been widened (Regulations 38 and 39);

  12. (l )

    the test requirements for all automatic weighing machines are set out in more detail (Schedules 1 and 2);

  13. (m )

    the prescribed limits of error for filling machines used only for weighing solid fuel have been reduced (Schedule 3 Table 1);

  14. (n)

    a requirement for the inspector to determine the repeatability error has been introduced for the material testings on discontinuous totalisers (Schedule 2 paragraphs 6(6) and 9(8) and Schedule 3 Table 2).