OpenLegislation

Paragraph 6.3.2.4.1 F1

A test report containing the following information shall be drawn up:

(a)

the product tested and its references;

(b)

the internal pressure and discharge rate of the aerosol dispenser;

(c)

the temperature and relative air humidity of the room;

(d)

for each test, the discharge time (s) needed to achieve ignition (if the product does not ignite, state this);

(e)

the mass of the product sprayed during each test (in g);

(f)

the actual volume of the drum (in dm3).

Annotations

Textual amendments

F1

Sch. 1A inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 13 para. 8 (with reg. 2 as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)