Division 4 Non-loadbearing elements or parts of works and products therefor
United Kingdom
| F1For cavity barriers this standard is complemented by EOTA TR 031. | ||||||||||
| Applies to | partitions (including partitions incorporating uninsulated portions, and cavity barriers) | |||||||||
| Standard(s) | EN13501-2; EN 1364-1 f1 ; EN 1992-1-2; EN 1993-1-2; EN 1994-1-2; EN 1995-1-2; EN 1996-1-2; EN 1999-1-2 | |||||||||
| Classification: - | ||||||||||
| E | 20 | 30 | 60 | 90 | 120 | |||||
| EI | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| EI-M | 30 | 60 | 90 | 120 | 180 | 240 | ||||
| EW | 20 | 30 | 60 | 90 | 120 | |||||
| Notes | — | |||||||||
| Applies to | ceilings with independent fire resistance | |||||||||
| Standard(s) | EN 13501-2; EN 1364-2 | |||||||||
| Classification: | ||||||||||
| EI | 15 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | ||
| Notes | The classification is completed by ‘(a → b)’, ‘(b → a)’, or ‘(a ↔ b)’ to indicate whether the element has been tested and fulfils the requirements from above or below only or both. | |||||||||
| Applies to | facades (curtain walls) and external walls (including glazed elements) | |||||||||
| Standard(s) | EN 13501-2; EN 1364-3,4,5,6; EN 1992-1.2; EN 1993-1.2; EN 1994-1.2; EN 1995-1.2; EN 1996-1.2; EN 1999-1.2 | |||||||||
| Classification: | ||||||||||
| E | 15 | 30 | 60 | 90 | 120 | |||||
| EI | 15 | 30 | 60 | 90 | 120 | |||||
| EW | 20 | 30 | 60 | |||||||
| Notes | The classification is completed by ‘(i → o)’, ‘(o → i)’, or ‘(i ↔ o)’ to indicate whether the element has been tested and fulfils the requirements from the inside or outside only or both. Where required, mechanical stability means that there are no falling parts liable to cause personal injury during the time for the E or EI classification. | |||||||||
| Applies to | raised floors | |||||||||
| Standard(s) | EN 13501-2; EN 1366-6 | |||||||||
| Classification: | ||||||||||
| R | 15 | 30 | ||||||||
| RE | 30 | |||||||||
| REI | 30 | |||||||||
| Notes | The classification is completed by the addition of the suffix ‘f’ to indicate full fire resistance or ‘r’ to indicate exposure to the reduced constant temperature exposure only. | |||||||||
| Applies to | penetration seals and linear gap seals | |||||||||
| Standard(s) | EN 13501-2; EN 1366-3,4 | |||||||||
| Classification: | ||||||||||
| E | 15 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | ||
| EI | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| Notes | — | |||||||||
| The ‘C’ classification may be complemented by the digits 0 to 5 according to the use category. Details shall be included in the relevant product technical specification. | ||||||||||
| Applies to | fire doors and shutters (including those that incorporate glazing and hardware) and their closing devices | |||||||||
| Standard(s) | EN 13501-2; EN 1634-1 | |||||||||
| Classification: | ||||||||||
| E | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| EI | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| EW | 20 | 30 | 60 | |||||||
| Notes | The I classification is completed by the addition of the suffix ‘1’ or ‘2’ to indicate which definition of insulation is used. The addition of the symbol ‘C’ indicates that the product also satisfies the ‘self-closing’ criterion (pass/fail test) f2. | |||||||||
| The ‘C’ classification may be complemented by the digits 0 to 5 according to the use category. Details shall be included in the relevant product technical specification. | |
| Applies to | smoke control doors |
| Standard(s) | EN 13501-2; EN 1634-3 |
| Classification: S200 or Sa depending upon the test conditions fulfilled | |
| Notes | The addition of the symbol ‘C’ indicates that the product also satisfies the ‘self-closing’ criterion (pass/fail test) f3. |
| The ‘C’ classification may be complemented by the digits 0 to 5 according to the use category. Details shall be included in the relevant product technical specification. | ||||||||||
| Applies to | closures for conveyers and trackbound transportation systems | |||||||||
| Standard(s) | EN 13501-2; EN 1366-7 | |||||||||
| Classification: | ||||||||||
| E | 15 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | ||
| EI | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| EW | 20 | 30 | 60 | |||||||
| Notes | F2The I classification is completed by the addition of the suffix ‘1’ or ‘2’ to indicate which definition of insulation is used. An I classification shall be generated for those cases where the test specimen is a pipe or duct configuration with no assessment of the closure for the conveyor system. The addition of the symbol ‘C’ indicates that the product also satisfies the ‘self-closing’ criterion (pass/fail test) f4. | |||||||||
| Applies to | service ducts and shafts | |||||||||
| Standard(s) | EN 13501-2; EN 1366-5 | |||||||||
| Classification: | ||||||||||
| E | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| EI | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| Notes | The classification is completed by ‘(i → o)’, ‘(o → i)’, or ‘(i ↔ o)’ to indicate whether the element has been tested and fulfils the requirements from the inside or outside only or both. In addition, the symbols ‘ve’ and/or ‘ho’ indicate the suitability for vertical and/or horizontal use. | |||||||||
| Applies to | chimneys |
| Standard(s) | EN 13501-2; EN 13216 |
| Classification: G + distance in mm (e.g. G 50) | |
| Notes | Distance not required for built-in products. |
| Notes | |||||||||
| The suffixes ‘ 1 ’ and ‘ 2 ’ indicate which substrates, fire behaviour criteria and extension rules are used in this classification. | |||||||||
| Applies to | Wall and ceiling coverings | ||||||||
| Standard(s) | EN 13501-2; EN 14135 | ||||||||
| Classification: | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| K 1 | 10 | ||||||||
| K 2 | 10 | 30 | 60 | ||||||
Annotations
Textual amendments
- F1
- F2
Footnotes
- f1
-
For cavity barriers this standard is complemented by EOTA TR 031.
- f2
-
The ‘C’ classification may be complemented by the digits 0 to 5 according to the use category. Details shall be included in the relevant product technical specification.
- f3
-
The ‘C’ classification may be complemented by the digits 0 to 5 according to the use category. Details shall be included in the relevant product technical specification.
- f4
-
The ‘C’ classification may be complemented by the digits 0 to 5 according to the use category. Details shall be included in the relevant product technical specification.