Division 4.2.5 Current at standstill (DC systems only)F1

United Kingdom Repealed

Original text. Later amendments are not shown.

  1. (1)

    The OCL of DC systems shall be designed to sustain 300 A (for a 1,5 kV supply system) and 200 A (for a 3 kV supply system), per pantograph when the train is at standstill.

  2. (2)

    The current capacity at standstill shall be achieved for the test value of static contact force given in table 4 of clause 7.2 of EN 50367:2012.

  3. (3)

    The OCL shall be designed taking into account the temperature limits in accordance with EN 50119:2009, clause 5.1.2.