OpenLegislation

Division 3.2.1.1.3.3.1 Methane conversion efficiency, EM

Original text. Later amendments are not shown.

The methane/air calibration gas shall be flowed to the FID through the NMC and bypassing the NMC and the two concentrations recorded. The efficiency shall be determined using the following equation:

EM=1−CHC(w/NMC)CHC(w/oNMC)

where:

CHC(w/NMC)
  • is the HC concentration with CH4 flowing through the NMC, ppm C;

  • CHC(w/oNMC)
  • is the HC concentration with CH4 bypassing the NMC, ppm C.