Division 3.2.1.1.3.3.2 Ethane conversion efficiency, EE
The ethane/air calibration gas shall be flowed to the FID through the NMC and bypassing the NMC and the two concentrations recorded. The efficiency shall be determined using the following equation:
where:
CHC(w/NMC) CHC(w/oNMC)
is the HC concentration with C2H6 flowing through the NMC, ppm C;
is the HC concentration with C2H6 bypassing the NMC, ppm C.
If the ethane conversion efficiency of the NMC is 0,98 or above, EE shall be set to 1 for any subsequent calculation.