OpenLegislation

Division 4.3.2 Utility factor-weighted electric energy consumption based on the recharged electric energy from the mains for OVC-HEVs

Original text. Later amendments are not shown.

The utility factor-weighted electric energy consumption based on the recharged electric energy from the mains shall be calculated using the following equation:

ECAC,weighted=∑j= 1kUFj× ECAC,CD,j

where:

ECAC,weighted
  • is the utility factor-weighted electric energy consumption based on the recharged electric energy from the mains, Wh/km;

  • UFj
  • is the utility factor of phase j according to Appendix 5 of this Sub-Annex;

  • ECAC,CD,j
  • is the electric energy consumption based on the recharged electric energy from the mains of phase j according to paragraph 4.3.1. of this Sub-Annex, Wh/km;

  • j
  • is the index number of the phase considered;

  • F1k
  • is the number of phases driven up to the end of the transition cycle in accordance with paragraph 3.2.4.4. of this Sub-Annex.

    in the case that the interpolation method is applied, k is the number of phases driven up to the end of the transition cycle of vehicle L, nveh_L.

  • Annotations

    Textual amendments

    F1

    Substituted by Commission Regulation (EU) 2018/1832 of 5 November 2018 amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) 2017/1151 for the purpose of improving the emission type approval tests and procedures for light passenger and commercial vehicles, including those for in-service conformity and real-driving emissions and introducing devices for monitoring the consumption of fuel and electric energy (Text with EEA relevance).