Division 4.3.2 Utility factor-weighted electric energy consumption based on the recharged electric energy from the mains for OVC-HEVs
The utility factor-weighted electric energy consumption based on the recharged electric energy from the mains shall be calculated using the following equation:
where:
is the utility factor-weighted electric energy consumption based on the recharged electric energy from the mains, Wh/km;
is the utility factor of phase j according to Appendix 5 of this Sub-Annex;
is the electric energy consumption based on the recharged electric energy from the mains of phase j according to paragraph 4.3.1. of this Sub-Annex, Wh/km;
is the index number of the phase considered;
is the number of phases driven up to the end of the transition cycle in accordance with paragraph 3.2.4.4. of this Sub-Annex.
in the case that the interpolation method is applied, k is the number of phases driven up to the end of the transition cycle of vehicle L, nveh_L.