For the fan power the standard values shown in Table 1 shall be used depending on mission profile and technology:

Table 1

Mechanical power demand of the fan

Fan drive clusterFan controlFan power consumption [W]
Long haulRegional deliveryUrban deliveryMunicipal utilityConstruction
Crankshaft mountedElectronically controlled visco clutch6186715165661 037
Bimetallic controlled visco clutch8188716767661 277
Discrete step clutch6687216166161 157
On/off cluch7187716666661 237
Belt driven or driven via transmissionElectronic controlled visco clutch9891 0448339331 478
Bimetallic controlled visco clutch1 1891 2449931 1331 718
Discrete step clutch1 0391 0949839831 598
On/off cluch1 0891 1441 0331 0331 678
Hydraulically drivenVariable displacement pump9381 1558329171 872
Constant displacement pump1 2001 4001 0001 1002 300
Electrically drivenElectronically7008006006001 400

If a new technology within a fan drive cluster (e.g. crankshaft mounted) cannot be found in the list the highest power values within that cluster shall be taken. If a new technology cannot be found in any cluster the values of the worst technology at all shall be taken (hydraulic driven constant displacement pump)