Paragraph 6 Other requirementsF1
The resolution shall be equal to or of one order of magnitude higher than the values shown in Table 3.
Table 3
| Resolution | ||||
|---|---|---|---|---|
| CO | CO2 | O2 | HC | |
| Class O and class I | 0.01 % vol | 0.1 % vol | 0.01 % vol for measurand values below or equal to 4 % vol, otherwise 0.1 % vol. | 1 ppm vol |
The lambda value shall be displayed with a resolution of 0.001.
The standard deviation of 20 measurements shall not be greater than one third of the modulus of the MPE for each applicable gas volume fraction.