Division 1.2.3 Determination of total cycle valuesF1
Table A6/1
Applicable rules for a manufacturer's declared values (total cycle values)f1
The declared value shall be the value to which the necessary corrections are applied (i.e. Ki, ATCT and DF corrections | |||||
Rounding xxx,xx | |||||
Rounding xxx,x | |||||
| Vehicle type | MCO2f2(g/km) | FC(kg/100 km) | Electric energy consumptionf3(Wh/km) | All electric range/Pure Electric Range(km) | |
|---|---|---|---|---|---|
| Vehicles tested in accordance with Sub-Annex 6 (pure ICE) | MCO2 Paragraph 3. of Sub-Annex 7. | — | — | — | |
| NOVC-FCHV | — | FCCS Paragraph 4.2.1.2.1. of Sub-Annex 8. | — | — | |
| NOVC-HEV | MCO2,CS Paragraph 4.1.1. of Sub-Annex 8. | — | — | — | |
| OVC-HEV | CD | MCO2,CD Paragraph 4.1.2. of. | — | ECAC,CD Paragraph 4.3.1. of Sub-Annex 8. | AER Paragraph 4.4.1.1. of Sub-Annex 8. |
| CS | MCO2,CS Sub-Annex 8 Paragraph 4.1.1. of Sub-Annex 8. | — | — | — | |
| PEV | — | — | ECWLTC Paragraph 4.3.4.2. of Sub-Annex 8. | PERWLTC Paragraph 4.4.2. of Sub-Annex 8. | |
Table A6/2
Criteria for number of tests
| For pure ICE vehicles, NOVC-HEVs and OVC-HEVs charge-sustaining Type 1 test. | ||||
Each test result shall fulfil the regulation limit. | ||||
| Test | Judgement parameter | Criteria emission | MCO2 | |
|---|---|---|---|---|
| Row 1 | First test | First test results | ≤ Regulation limit × 0,9 | ≤ Declared value × dCO21 |
| Row 2 | Second test | Arithmetic average of the first and second test results | ≤ Regulation limit × 1,0f4 | ≤ Declared value × dCO22 |
| Row 3 | Third test | Arithmetic average of three test results | ≤ Regulation limit × 1,0 | ≤ Declared value × dCO23 |
| For OVC-HEVs charge-depleting Type 1 test. | |||||
‘0,9’ shall be replaced by ‘1,0’ for charge-depleting Type 1 test for OVC-HEVs, only if the charge-depleting test contains two or more applicable WLTC cycles. | |||||
Each test result shall fulfil the regulation limit. | |||||
| Test | Judgement parameter | Criteria emissions | MCO2,CD | AER | |
|---|---|---|---|---|---|
| Row 1 | First test | First test results | ≤ Regulation limit × 0,9f5 | ≤ Declared value × dCO21 | ≥ Declared value × 1,0 |
| Row 2 | Second test | Arithmetic average of the first and second test results | ≤ Regulation limit × 1,0f6 | ≤ Declared value × dCO22 | ≥ Declared value × 1,0 |
| Row 3 | Third test | Arithmetic average of three test results | ≤ Regulation limit × 1,0 | ≤ Declared value × dCO23 | ≥ Declared value × 1,0 |
| For PEVs | ||||
| Test | Judgement parameter | Electric energy consumption | PER | |
|---|---|---|---|---|
| Row 1 | First test | First test results | ≤ Declared value × 1,0 | ≥ Declared value × 1,0 |
| Row 2 | Second test | Arithmetic average of the first and second test results | ≤ Declared value × 1,0 | ≥ Declared value × 1,0 |
| Row 3 | Third test | Arithmetic average of three test results | ≤ Declared value × 1,0 | ≥ Declared value × 1,0 |
| For NOVC-FCHVs | |||
| Test | Judgement parameter | FCCS | |
|---|---|---|---|
| Row 1 | First test | First test results | ≤ Declared value × 1,0 |
| Row 2 | Second test | Arithmetic average of the first and second test results | ≤ Declared value × 1,0 |
| Row 3 | Third test | Arithmetic average of three test results | ≤ Declared value × 1,0 |
- 1.2.3.1Division 1.2.3.1
- 1.2.3.2Division 1.2.3.2
- 1.2.3.3Division 1.2.3.3
- 1.2.3.4Division 1.2.3.4
- 1.2.3.5Division 1.2.3.5
- 1.2.3.6Division 1.2.3.6
- 1.2.3.7Division 1.2.3.7
- 1.2.3.8Determination of the acceptance value dCO21, dCO22 and dCO23
- 1.2.3.9Division 1.2.3.9
- Figure A6/1Flowchart for the number of Type 1 tests
Annotations
Textual amendments
Footnotes
- f1
The declared value shall be the value to which the necessary corrections are applied (i.e. Ki, ATCT and DF corrections
- f2
Rounding xxx,xx
- f3
Rounding xxx,x
- f4
Each test result shall fulfil the regulation limit.
- f5
‘0,9’ shall be replaced by ‘1,0’ for charge-depleting Type 1 test for OVC-HEVs, only if the charge-depleting test contains two or more applicable WLTC cycles.
- f6
Each test result shall fulfil the regulation limit.